 Agilent Technologies InfiniiVision MSO N5406A FPGA Dynamic Probe for Xilinx
Data Sheet
Figure 1. FPGA dynamic probe for Xilinx used in conjunction with an Agilent InfiniiVision 6000 or 7000 Series MSO provides an effective solution for simple through complex debugging of systems incorporating Xilinx FPGAs.
The challenge
You rely on the insight a MSO (mixed-signal oscilloscope) provides to understand the behavior of your FPGA in the context of the surrounding system. Design engineers typically take advantage of the programmability of the FPGA to route internal nodes to a small number of physical pins for debugging. While this approach www..com is very useful, it has significant limitations.
* Since pins on the FPGA are typically an expensive resource, there are a relatively small number available for debug. This limits internal visibility (i.e. one pin is required for each internal signal to be probed). * When you need to access different internal signals, you must change your design to route these signals to the available pins. This can be time consuming and can affect the timing of your FPGA design.
* Finally, the process required to map the signal names from your FPGA design to the MSO digital channel labels is manual and tedious. When new signals are routed out, you need to manually update these signal names on the MSO, which takes additional time and is a potential source of confusing errors.
Debug your FPGAs faster and more effectively with a MSO
A better way - Collaborative development between Agilent and Xilinx have produced a faster and more effective way to use your MSO to debug FPGAs and the surrounding system. The Agilent FPGA dynamic probe, used in conjunction with an Agilent MSO, provides the most effective solution for simple through complex debugging. View internal activity - With the digital channels on your MSO, you are normally limited to measuring signals at the periphery of the FPGA. With the FPGA dynamic probe, you can now access signals internal to the FPGA. You can measure up to 64 internal signals for each external pin dedicated to debug, unlocking visibility into your design that you never had before. Make multiple measurements in seconds - Moving probe points internal to an FPGA used to be time consuming. Now, in less than a second, you can easily measure different sets of internal signals without design changes. FPGA timing stays constant when you select new sets of internal signals for probing. Leverage the work you did in your design environment - The FPGA dynamic probe maps internal signal names from your FPGA design tool to your Agilent MSO. Eliminate unintentional mistakes and save hours of time with this automatic setup of signal and bus names on your MSO.
www..com
Probe outputs on FPGA pins PC board FPGA
ATC2
SW application can be licensed to a particular PC or particular MSO
SW application installed on a PC connected to 6000 or 7000 Series MSOs
USB LAN GPIB Parallel or USB
JTAG Insert ATC2 core with Xilinx Core Inserter
Xilinx JTAG Cable
Figure 2. Create a timesaving FPGA measurement system. Insert an ATC2 (Agilent Trace Core) core into your FPGA design. With the application running on your PC you control which group of internal signals to measure via JTAG.
1-128
Selection MUX
1-128 1-128
1-128
To FPGA pins
1-128
Change signal bank selection via JTAG
JTAG Figure 3. Access up to 64 internal signals for each debug pin. Signal banks all have identical width (1 to 128 signals wide) determined by the number of device pins you devote for debug. Each pin provides sequential access to one signal from every input bank.
2
Select
A quick tour of the application
Design step 1: Create the ATC2 core Use Xilinx Core Inserter or EDK to select your ATC2 parameters and to create a debug core that best matches your development needs. Parameters include number of pins, number of signal banks, the type of measurement (state or timing), and other ATC2 attributes.
Design step 2: Select groups of signals to probe Specify banks of internal signals that are potential candidates for MSO measurements (using Xilinx Core Inserter or EDK).
Activate FPGA dynamic probe for Xilinx The FPGA dynamic probe application allows you to control the ATC2 core and set www..com up the MSO for the desired measurements. This application runs on a PC.
3
A quick tour of the application (continued)
Connect your MSO to your PC From FPGA dynamic probe application software, specify the communication link between your PC and MSO.
Measurement setup step 1: Establish a connection between the PC and the ATC2 core The FPGA dynamic probe application establishes a connection between the PC and a Xilinx cable. It also determines what devices are on the JTAG scan chain and lets you pick which one you wish to communicate with. Core and device names are user definable.
Measurement setup step 2: Map FPGA pins Quickly specify how the FPGA pins (the signal outputs of ATC2) are connected to your MSO. Select your probe type and rapidly provide the information needed for the MSO to automatically track names of www..com signals routed through the ATC2 core.
4
A quick tour of the application (continued)
For ATC2 cores with auto setup enabled, each pin of the ATC2 core, one at a time, produces a unique stimulus pattern. The instrument looks for this unique pattern on any of its acquisition channels. When the instrument finds the pattern, it associates that instrument channel with the ATC2 output pin producing it. It then repeats the process for each of the remaining output pins eliminating the need to manually enter probe layout information.
Measurement setup step 3: Import signal names Tired of manually entering bus and signal names on your MSO? The FPGA dynamic probe application reads a .cdc file produced by Xilinx Core Inserter. The names of signals you measure will now automatically show on your MSO digital channel labels.
Setup complete: Make measurements Quickly change which signal bank is routed to the MSO. A single mouse click tells the ATC2 core to switch to the newly specified signal bank without any impact to the timing of your design. To make measurements throughout your FPGA, change signal banks as often as needed. www..com User-definable signal bank names make it straight forward to select a part of your design to measure.
5
A quick tour of the application (continued)
Triggering on valid states MSOs incorporate logic state triggering for triggering on specific states. Set up a valid state trigger by specifying the clock edge and the desired bus/ signal pattern. Because the ATC2 core outputs both the clock signal and bus values, triggering on the combination ensures your state trigger is valid--even though the digital channels are sampling asynchronously. Track valid states by measuring the bus value on each falling clock edge for image shown.
Automatic bus groupings InfiniiVision MSOs include up to 2 bus groupings. Contiguous signal names are automatically grouped and displayed as buses. Bus values can be displayed as HEX or binary values. Additional signals are shown using independent waveforms.
Correlate internal FPGA activity with external measurements View internal FPGA activity and time-correlate internal FPGA measurements with external analog and digital events in the surrounding system. FPGA Dynamic Probe unlocks the power of the MSO for www..com system-level debug with FPGAs.
6
Agilent N5406A specifications and characteristics
Supported logic analyzers Standalone oscilloscopes MSO Digital Channels Bus groupings Triggering capabilities Supported Xilinx FPGA families Supported Xilinx cables (required) Supported probing mechanisms InfiniiVision 6000 and 7000 Series MSOs 16 Up to 2, each with 6 character labels Determined by MSO, all have state triggering Virtex-5, Virtex-4, Virtex-II Pro series, Virtex-II series, Spartan-3 generation Parallel 3 and 4, Platform Cable USB Soft touch (34-channel and 17-channel), Mictor, Samtec, Flying lead, 6000 and 7000 Series MSOs come standard with a 40 pin probe cable and flying leads. Cables and probing for Mictor, soft touch, or Samtec probing must be purchased separately.
Agilent trace core characteristics Number of output signals Signal banks Modes FPGA Resource consumption User definable: Clock line plus 4 to 128 signals in 1 signal increments User definable: 1, 2, 4, 8, 16, 32, or 64 State (synchronous) or timing (asynchronous) mode Approximately 1 slice required per input signal to ATC2 Core Consumes no BUFGs, DCM or Block RAM resources. See resource calculator at www.agilent.com/find/fpga
Compatible design tools
ChipScope Pro version 6.2i, 6.3i Agilent MSO FPGA dynamic probe SW version 1.0 or higher Primary new features Mouse-click bank select, graphical pin mapping, cdc signal name import Plug & run (auto pin mapping), ATC2 "always on" option, ATC2 width + 64 banks, Platform Cable USB support, PRBS stimulus on test bank Support for Virtex-5 devices, MSO bus groupings
7.1i
2.03 or higher
8.2i
2.10 or higher
EDK (Embedded Development Kit) 8.1i SP2 2.03 or higher Synthesis
Support for ATC2 core using EDK flow Core Inserter produces ATC2 cores postsynthesis (pre-place and route) making the cores synthesis independent. ATC2 cores produced by Core Generator are compatible with: * Exemplar Leonardo Spectrum * Synopsys Design Compiler * Synopsys Design Compiler II * Synopsys FPGA Express * Synplicity Synplify * Xilinx XST
www..com
Additional information available via the Internet: www.agilent.com/find/FPGA and www.agilent.com/find/6000-xilinx. 7
Ordering information
Ordering options for the Agilent N5405A FPGA dynamic probe for Xilinx Option 001 Option 002 * Entitlement certificate for perpetual node-locked license locked to oscilloscope (most common). * Entitlement certificate for PC locked license. PC and MSO must both connect to LAN. USB, or GPIB
Related literature
Publication title Frequently Asked Questions MSO FPGA Dynamic Probe for Xilinx Agilent Technologies 6000 Series Oscilloscopes Agilent Technologies Infiniium MSO8000 N5397A FPGA Dynamic Probes for Xilinx Agilent Technologies InfiniiVision 7000 Series Oscilloscopes Publication type Data Sheet Data Sheet Data Sheet Data Sheet Publication number 5989-5976EN 5989-2000EN 5989-1848EN 5989-7736EN
Product Web site
For the most up-to-date and complete application and product information, please visit our product Web site at: www.agilent.com/find/scopes
www..com
8
www.agilent.com
Agilent Email Updates
www.agilent.com/find/emailupdates Get the latest information on the products and applications you select.
Remove all doubt
Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilenttrained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt
For more information on Agilent Technologies' products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada Latin America United States Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Thailand 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 1 800 226 008 (877) 894-4414 305 269 7500 (800) 829-4444
Agilent Direct
www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence.
Agilent Open
www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of system-ready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development.
Europe & Middle East Austria Belgium Denmark Finland France Germany Ireland Israel Italy Netherlands Spain Sweden Switzerland 0820 87 44 11 32 (0) 2 404 93 40 45 70 13 15 15 358 (0) 10 855 2100 0825 010 700*
*0.125 fixed network rates
01805 24 6333**
**0.14 /minute
www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium.
1890 924 204 972-3-9288-504/544 39 02 92 60 8484 31 (0) 20 547 2111 34 (91) 631 3300 0200-88 22 55 (French) 44 (21) 8113811 (Opt 2) Switzerland (German) 0800 80 53 53 (Opt 1) United Kingdom 44 (0) 118 9276201 Other European countries: www.agilent.com/find/contactus
Revised: October 24, 2007
www..com
Product specifications and descriptions in this document subject to change without notice. (c) Agilent Technologies, Inc. 2006, 2008 Printed in USA, March 7, 2008 5989-5965EN